  • 產品名稱:Vermason 222547校準器

  • 產品型號:用于校準手腕帶和工鞋接地測試儀
  • 產品廠商:其它品牌
  • 產品文檔:
你添加了1件商品 查看購物車
簡單介紹:
Vermason 222547校準器 Calibration Unit for Vermason Wrist Strap and Footwear Tester用于校準手腕帶和工鞋接地測試儀適配儀器:222504, 222506,222507, 222562, 222563, 222564, 222565,Vermason(DESCO子品牌)
詳情介紹:

Vermason 222547校準器 Calibration Unit for Vermason Wrist Strap and Footwear Tester
用于校準手腕帶和工鞋接地測試儀
適配儀器:222504, 222506,222507, 222562, 222563, 222564, 222565
Vermason(DESCO子品牌)

Operation
The Tester Calibration Unit was specifically designedfor use in calibration of Vermason brand equipment.The following procedures will not cover adjustment of
the test equipment. For detailed information regardingadjustment of specific Vermason brand testers, pleasecontact Desco Europe Customer Service.

Frequency of recalibration should be based on thecritical nature of those ESD sensitive items handled andthe risk of failure for the ESD protective equipment andmaterials. In general, we recommend that calibration be
performed annually.

Testing the Compact Tester
WRIST STRAP CIRCUIT
1. Connect the 10 mm lead from the Calibration Unitto the wrist strap stud on the Compact Tester.
2. Select 715K FAIL LOW on the Calibration Unit.
3. Press and hold the Calibration Unit’s test probeon the Compact Tester’s test plate. The testershould indicate a FAIL LOW condition.
4. Select 785K PASS LOW on the Calibration Unitand repeat the test. The tester should indicate aPASS condition.
5. Select 33M PASS HIGH on the Calibration Unitand repeat the test. The tester should indicate aPASS condition.
6. Select 37M FAIL HIGH on the Calibration Unitand repeat the test. The tester should indicate aFAIL HIGH condition.

FOOTWEAR CIRCUIT
1. Connect the 10 mm lead from the Calibration Unitto the 10 mm footwear stud on the Compact Tester.
2. Select 715K FAIL LOW on the Calibration Unit.
3. Press and hold the Calibration Unit’s test probeon the Compact Tester’s test plate. The testershould indicate a FAIL LOW condition.
4. Select 785K PASS LOW on the Calibration Unitand repeat the test. The tester should indicate aPASS condition.
5. Select 33M PASS HIGH on the Calibration Unitand repeat the test. The tester should indicate aPASS condition.
6. Select 37M FAIL HIGH on the Calibration Unit andrepeat the test. The tester should indicate aFAIL HIGH condition

姓名:
電話:
您的需求:
 
主站蜘蛛池模板: 丁香五香天堂网卡| 久草资源视频| 婷婷精品在线| 男女免费视频| 精品午夜视频| 国产精品久久久久久久久久久久| 狠狠干天天爽| 婷婷5月天| 日韩高清一级| 你懂的国产视频| 久久婷婷国产综合精品青草| 国产女人综合久久精品视| 99热在线看| 久久综合给会久久狠狠狠| 国产一及毛片| 日韩欧美中字| 片免费观看在线看| 欧美看片网站| 毛片网站在线观看| 久久免费香蕉视频| 九九热免费观看| 国产一区二区视频免费| 国产大学生系列| 东京天堂热| 不卡一区| 99亚洲精品| 99国产精品| 99爱免费观看视频在线| 国产亚洲欧美日韩在线观看不卡| 五月天色婷婷综合| 五月开心激情网| 污污的视频网站| 亭亭色| 天天精品| 我和岳交换夫妇中文字幕在线| 天堂在线国产| 五月天激情社区| 高清一级毛片免免费看| 午夜精品久久久| 草人人| 久久精品日日躁夜夜躁欧美|